Equipment
stand
bosses x 3
clamps x 3
G-clamp
metre rule
light spring
700 g of slotted masses including hanger
stopwatch
Method
- Use the G-clamp to secure the base of the stand to a desk.
- Fix a metre rule in the vertical position using two of the bosses and clamps.
- Using the other boss and clamp, position a spring near to the top of the stand so the spring hangs vertically down in front of the metre rule.
- Adjust the mass of the hanger to 700 g, and suspend it from the spring.
- Remove the 700 g mass to ensure that the spring has not deformed.
- Suspend the mass from the spring and note the approximate position of the mass once at rest.
- Ensure that the mass can oscillate up and down without touching the metre rule.
- Pull the mass down by 3 cm and then release.
- Once the mass is oscillating, time how long it takes for 10 complete oscillations.
- Repeat steps 6-8 twice more and take an average.
- Repeat steps 6-9 for masses of 600 g, 500 g, 400 g, and 300 g.
Risk assessment
stand
Method
hazard | risk | probability | mitigation |
---|---|---|---|
heavy equipment | crush injuries | low | position masses away from table edge; use G-clamp to secure stand |
spring | sharp wires | low | don't overload the light spring; wear goggles |
Images
No comments: